Case 1
- Thickness d
- 0.1m
- Thermal conductivity k
- 0.04W/(m·K)
- Area A
- 10m²
0.250000K/W
Open with these valuesChange any value to update the result.
0.250000K/W
Thermal resistance: 0.250000 K/WYour current valid inputs, with one value varied across the range.
Held fixed: Thickness d 0.1000 m, Thermal conductivity k 0.0400 W/(m·K).
| Area A (m²) | Thermal resistance (K/W) |
|---|---|
| 8.0000 | 0.312500 |
| 10.0000Your value | 0.250000 |
| 12.0000 | 0.208333 |
Thermal resistance is how many kelvin of difference it takes to push one watt through a layer: R = d ÷ (k × A). A 10 m² wall of mineral wool 100 mm thick comes to 0.25 K/W. Higher is better insulation — and the heat flow that follows is simply ΔT ÷ R.
0.250000K/W
Open with these values0.012000K/W
Open with these values0.000125K/W
Open with these valuesR = d ÷ (k × A)
| d, k, A | What that could be | Resistance in K/W |
|---|---|---|
| 0, 0.04, 10 | no layer at all | 0.000000 |
| 0.05, 400, 1 | 50 mm of copper over 1 m² | 0.000125 |
| 0.012, 1, 1 | 12 mm of glass over 1 m² | 0.012000 |
| 0.1, 0.04, 10 | 100 mm of mineral wool over 10 m² | 0.250000 |
| 0.15, 0.04, 5 | 150 mm of mineral wool over 5 m² | 0.750000 |
| 0.2, 0.025, 1 | 200 mm of still air over 1 m² | 8.000000 |
Divide the thickness by the conductivity times the area: R = d ÷ (k × A). A 0.1 m panel of 0.04 W/(m·K) over 10 m² gives 0.1 ÷ 0.4 = 0.25 K/W.
It is how strongly a layer opposes heat passing through it, measured in kelvin per watt. The value is the temperature difference needed to drive exactly one watt across the layer.
The R-value used in construction is area-specific, R = d ÷ k in m²·K/W, and describes one square metre of material. This calculator divides by the area as well and gives the resistance of the whole component in K/W.
For insulation, higher is better — less heat escapes through the wall, window or roof. For a heat sink or a pan you want it low, so heat leaves quickly.
This one answers how hard the layer makes it, in K/W, using only its geometry and material. The conduction calculator adds a temperature difference and answers how many watts actually get through, and the two are linked by Q = ΔT ÷ R.
Diese Seite gibt es auch auf Deutsch.